High-Resolution Laser Beam Profiling System LaserCam-HR II is our second generation of digital USB 2.0 bus-powered, high-resolution, large-area cameras. The LaserCam-HR II family includes 1/2-inch and 2/3-inch format CCD cameras…
LaserCam-HR II is our second generation of digital USB 2.0 bus-powered, high-resolution, large-area cameras. The LaserCam-HR II family includes 1/2-inch and 2/3-inch format CCD cameras that provide greater dynamic range and lower noise than the previous generation. The cameras include Coherent’s BeamView software package, long recognized as a flexible, fast, and user friendly beam diagnostics software platform. The UV model provides long-term UV sensor stability.

Contact Nam Sơn to receive a detailed quotation and consultation on the right laser solution for your business via hotline
| SPECIFICATIONS¹ | LaserCam-HR II 1/2-inch | LaserCam-HR II 2/3-inch | LaserCam-HR II UV 2/3-inch |
| Sensor Elements (pixels) | 1280 x 1024 | ||
| Effective Pixel Resolution (µm) | n/a | n/a | 20 x 20 |
| Pixel Size (μm) | 4.6 x 4.6 | 6.5 x 6.5 | n/a |
| Sensor Active Area (mm) (H x V) | 5.9 x 4.8 | 8.3 x 6.6 | 8.3 x 6.6 |
| Camera Bit Depth | 12-bit | 14-bit | 14-bit |
| Spectral Range (nm)
without LDFP with LDFP included with BIP-12F accessory |
190 to 1100¹ 400 to 1100 190 to 355 |
190 to 1100¹ 400 to 1100 190 to 355 |
190 to 355
|
| Recommended Beam Diameters (mm) | 0.15 to 4.0(2) | 0.2 to 6.0(2) | 0.5 to 6.0 |
| Capture Modes | Continuous (CW), pulsed | ||
| Variable Exposure Time | 1 msec to 500 msec, default at 5 msec |
1 msec to 500 msec, default at 5 msec |
1 msec to 500 msec, default at 5 msec |
| Trigger Delay (µs) | 75 | 20 | 20 |
| Maximum Pulse Trigger in Rate(3) (Hz) | 200 | 200 | 200 |
| Damage Threshold without LDFP | 32 mJ/cm² at 1064 nm | 32 mJ/cm² at 1064 nm | 200 µJ/cm² at 1064 nm(4) |
| CW Saturation
with LDFP without LDFP with LDFP without LDFP |
13 mW/cm² at 633 nm 5 μW/cm² at 633 nm 70 mW/cm² at 1064 nm 340 μW/cm² at 1064 nm |
5 mW/cm² at 633 nm 2 μW/cm² at 633 nm 25 mW/cm² at 1064 nm 125 μW/cm² at 1064 nm |
90 mW/cm² at 248 nm(5) 90 µW/cm² at 248 nm(4)
|
| Pulsed Saturation
with LDFP without LDFP |
0.4 mJ/cm² at 1064 nm 2 μJ/cm² at 1064 nm |
0.15 mJ/cm² at 1064 nm 0.7 μJ/cm² at 1064 nm |
5 mJ/cm² at 248 nm(5) 5 μJ/cm² at 248 nm(4) |
| USB 2.0 Cable | 10 ft. standard A/B cable included | ||
| Trigger | Connector BNC receptacle (trigger cable included) | ||
| Part Number | 1282868 | 1282870 | 1360550 |
1 There is a risk of degradation in the range of 190 nm to 300 nm due to DUV exposure. The optional BIP-12F UV-to-visible fluorescence converter can be used to prevent drift.
2 It is possible to measure beams <0.2 mm in diameter, but resolution is reduced.
3 Without averaging adjacent pulses.
4 Without LDFP-UV.
5 With LDFP-UV.
LaserCam-HR II