Nam Sơn

LASERCAM-HR II

High-Resolution Laser Beam Profiling System LaserCam-HR II is our second generation of digital USB 2.0 bus-powered, high-resolution, large-area cameras. The LaserCam-HR II family includes 1/2-inch and 2/3-inch format CCD cameras…

Details
Liên hệ tư vấn

APPLICATION

FUNCTION
Accessories

PRODUCT DESCRIPTION

High-Resolution Laser Beam Profiling System

LaserCam-HR II is our second generation of digital USB 2.0 bus-powered, high-resolution, large-area cameras. The LaserCam-HR II family includes 1/2-inch and 2/3-inch format CCD cameras that provide greater dynamic range and lower noise than the previous generation. The cameras include Coherent’s BeamView software package, long recognized as a flexible, fast, and user friendly beam diagnostics software platform. The UV model provides long-term UV sensor stability.

High-resolution-Laser-beam-profiling-system

Contact Nam Sơn to receive a detailed quotation and consultation on the right laser solution for your business via hotline

FEATURES & BENEFITS

  • USB 2.0, 12-bit and 14-bit digital output
  • Large-area arrays
  • Compact 68 x 68 x 43 mm package
  • Metric and English mounts included
  • CW and pulsed operation including external triggering
  • Variable exposure time
  • User-variable trigger delay
  • C-mount thread for additional accessories

OPTIONS & ACCESSORIES

  • Scientific
  • UV Lasers
  • Telecommunication Sources
  • Military Laser Systems
SPECIFICATIONS¹ LaserCam-HR II 1/2-inch LaserCam-HR II 2/3-inch LaserCam-HR II UV 2/3-inch
Sensor Elements (pixels) 1280 x 1024
Effective Pixel Resolution (µm) n/a n/a 20 x 20
Pixel Size (μm) 4.6 x 4.6 6.5 x 6.5 n/a
Sensor Active Area (mm) (H x V) 5.9 x 4.8 8.3 x 6.6 8.3 x 6.6
Camera Bit Depth 12-bit 14-bit 14-bit
Spectral Range (nm)

without LDFP

with LDFP included

with BIP-12F accessory

 

190 to 1100¹

400 to 1100

190 to 355

 

190 to 1100¹

400 to 1100

190 to 355

190 to 355

 

Recommended Beam Diameters (mm) 0.15 to 4.0(2) 0.2 to 6.0(2) 0.5 to 6.0
Capture Modes Continuous (CW), pulsed
Variable Exposure Time 1 msec to 500 msec,
default at 5 msec
1 msec to 500 msec,
default at 5 msec
1 msec to 500 msec,
default at 5 msec
Trigger Delay (µs) 75 20 20
Maximum Pulse Trigger in Rate(3) (Hz) 200 200 200
Damage Threshold without LDFP 32 mJ/cm² at 1064 nm 32 mJ/cm² at 1064 nm 200 µJ/cm² at 1064 nm(4)
CW Saturation

with LDFP

without LDFP

with LDFP

without LDFP

 

13 mW/cm² at 633 nm

5 μW/cm² at 633 nm

70 mW/cm² at 1064 nm

340 μW/cm² at 1064 nm

 

5 mW/cm² at 633 nm

2 μW/cm² at 633 nm

25 mW/cm² at 1064 nm

125 μW/cm² at 1064 nm

 

90 mW/cm² at 248 nm(5)

90 µW/cm² at 248 nm(4)

 

 

Pulsed Saturation

with LDFP

without LDFP

 

0.4 mJ/cm² at 1064 nm

2 μJ/cm² at 1064 nm

 

0.15 mJ/cm² at 1064 nm

0.7 μJ/cm² at 1064 nm

 

5 mJ/cm² at 248 nm(5)

5 μJ/cm² at 248 nm(4)

USB 2.0 Cable 10 ft. standard A/B cable included
Trigger Connector BNC receptacle (trigger cable included)
Part Number 1282868 1282870 1360550

1 There is a risk of degradation in the range of 190 nm to 300 nm due to DUV exposure. The optional BIP-12F UV-to-visible fluorescence converter can be used to prevent drift.
2 It is possible to measure beams <0.2 mm in diameter, but resolution is reduced.
3 Without averaging adjacent pulses.
4 Without LDFP-UV.
5 With LDFP-UV.

MECHANICAL SPECIFICATIONS

LaserCam-HR II

Mechanical Specifications of High-Resolution Laser Beam Profiling System

Mechanical Specifications of High-Resolution Laser Beam Profiling System